티스토리 뷰

Horse Testo(Testosterone) ELISA Kit

Cat. # ELK8556 / Size: 48T, 96T

 

 

Overview

Product name:
Horse Testo(Testosterone) ELISA Kit
Reactivity:
Horse
Alternative Names:
T; Testesteron; Testeronun
Assay Type:
Competitive Inhibition
Sensitivity:
17.7 pg/mL
Standard:
4000 pg/mL
Range:
62.5-4000 pg/mL
Sample Type:
serum, plasma, other biological fluids
Assay Length:
2h
Research Area:
Endocrinology;Reproductive science;Hormone metabolism;
Test principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Horse Testo protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Horse Testo. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Horse Testo in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard Curve

Concentration (ng/mL)
OD
Corrected OD
4000.00
0.235
2000.00
0.386
1000.00
0.689
500.00
0.895
250.00
1.257
125.00
1.587
62.50
1.624
0.00
2.232

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant Testo and the recovery rates were calculated by comparing the measured value to the expected amount of Testo in samples.

Matrix
Recovery range
Average
serum(n=5)
82-95%
88%
EDTA plasma(n=5)
85-97%
91%
Heparin plasma(n=5)
79-93%
90%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Testo and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix
1:2
1:4
1:8
1:16
serum(n=5)
85-96%
87-101%
89-101%
85-97%
EDTA plasma(n=5)
86-93%
93-101%
85-98%
90-101%
Heparin plasma(n=5)
92-101%
89-97%
85-94%
87-101%

코아사이언스 coresciences Korea ELK Biotechnology CO.,LTD ELK (Wuhan) Biotechnology CO.,Ltd. 한국 대리점 ELISA antibody 항체 면역학 연구 세포배양 분자생물학 시약