티스토리 뷰
Horse Testo(Testosterone) ELISA Kit [ELK8556]_ELK Biotechnology - 코아사이언스
코피디 2024. 1. 2. 16:24Horse Testo(Testosterone) ELISA Kit
Cat. # ELK8556 / Size: 48T, 96T
Overview
Product name:
|
Horse Testo(Testosterone) ELISA Kit
|
Reactivity:
|
Horse
|
Alternative Names:
|
T; Testesteron; Testeronun
|
Assay Type:
|
Competitive Inhibition
|
Sensitivity:
|
17.7 pg/mL
|
Standard:
|
4000 pg/mL
|
Range:
|
62.5-4000 pg/mL
|
Sample Type:
|
serum, plasma, other biological fluids
|
Assay Length:
|
2h
|
Research Area:
|
Endocrinology;Reproductive science;Hormone metabolism;
|
Test principle:
|
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Horse Testo protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Horse Testo. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Horse Testo in the samples is then determined by comparing the OD of the samples to the standard curve.
|
Standard Curve
Concentration (ng/mL)
|
OD
|
Corrected OD
|
4000.00
|
0.235
|
—
|
2000.00
|
0.386
|
—
|
1000.00
|
0.689
|
—
|
500.00
|
0.895
|
—
|
250.00
|
1.257
|
—
|
125.00
|
1.587
|
—
|
62.50
|
1.624
|
—
|
0.00
|
2.232
|
—
|
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant Testo and the recovery rates were calculated by comparing the measured value to the expected amount of Testo in samples.
Matrix
|
Recovery range
|
Average
|
serum(n=5)
|
82-95%
|
88%
|
EDTA plasma(n=5)
|
85-97%
|
91%
|
Heparin plasma(n=5)
|
79-93%
|
90%
|
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Testo and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix
|
1:2
|
1:4
|
1:8
|
1:16
|
serum(n=5)
|
85-96%
|
87-101%
|
89-101%
|
85-97%
|
EDTA plasma(n=5)
|
86-93%
|
93-101%
|
85-98%
|
90-101%
|
Heparin plasma(n=5)
|
92-101%
|
89-97%
|
85-94%
|
87-101%
|
![](https://blog.kakaocdn.net/dn/QVPkB/btsC00gLVqV/ItqF9qbaaofFBUfwICwXKK/img.jpg)
코아사이언스 coresciences Korea ELK Biotechnology CO.,LTD ELK (Wuhan) Biotechnology CO.,Ltd. 한국 대리점 ELISA antibody 항체 면역학 연구 세포배양 분자생물학 시약
'ELISA,항체,단백질' 카테고리의 다른 글
- Total
- Today
- Yesterday
- allview PAGE buffer
- Funakoshi
- 연속절편
- OPV
- OLED
- matrix-driven delivery pellet
- 형광염색
- 오토클레이브백
- filter
- 조직염색절편제작
- 바이오헤저드백
- 코아사이언스
- time release pellets
- 조직절편
- gradient gel
- 면역화학분석
- 바이오하자드백
- solar cells
- 고수용성 콘드로이틴
- 조직절편제작
- Coresciences
- 건스터바이오텍
- 파라핀 블럭
- 파라핀 블록
- Sterlitech
- 후나코시
- 콘드로이틴 황산 올리고당
- material science
- 막필터
- 미니멸균백
일 | 월 | 화 | 수 | 목 | 금 | 토 |
---|---|---|---|---|---|---|
1 | ||||||
2 | 3 | 4 | 5 | 6 | 7 | 8 |
9 | 10 | 11 | 12 | 13 | 14 | 15 |
16 | 17 | 18 | 19 | 20 | 21 | 22 |
23 | 24 | 25 | 26 | 27 | 28 |