Cat. # ELK8547 / Size: 48T, 96T
Overview
Product name:
|
Horse E2(Estradiol) ELISA Kit
|
Reactivity:
|
Horse
|
Alternative Names:
|
17B-Estradiol; Oestradiol; Beta-Estradiol
|
Assay Type:
|
Competitive Inhibition
|
Sensitivity:
|
4.72 pg/mL
|
Standard:
|
1000 pg/mL
|
Range:
|
15.63-1000 pg/mL
|
Sample Type:
|
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
|
Assay Length:
|
2h
|
Research Area:
|
Endocrinology;Reproductive science;Hormone metabolism;
|
Test principle:
|
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Horse E2 protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Horse E2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Horse E2 in the samples is then determined by comparing the OD of the samples to the standard curve.
|
Standard Curve
Concentration (ng/mL)
|
OD
|
Corrected OD
|
1000.00
|
0.227
|
—
|
500.00
|
0.375
|
—
|
250.00
|
0.583
|
—
|
125.00
|
0.897
|
—
|
62.50
|
1.197
|
—
|
31.25
|
1.511
|
—
|
15.63
|
1.813
|
—
|
0.00
|
2.211
|
—
|
Precision
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Recovery
Matrices listed below were spiked with certain level of recombinant E2 and the recovery rates were calculated by comparing the measured value to the expected amount of E2 in samples.
Matrix
|
Recovery range
|
Average
|
serum(n=5)
|
93-101%
|
97%
|
EDTA plasma(n=5)
|
85-103%
|
94%
|
Heparin plasma(n=5)
|
95-105%
|
88%
|
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of E2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix
|
1:2
|
1:4
|
1:8
|
1:16
|
serum(n=5)
|
92-101%
|
82-98%
|
85-96%
|
85-95%
|
EDTA plasma(n=5)
|
86-99%
|
93-107%
|
85-94%
|
87-101%
|
Heparin plasma(n=5)
|
92-101%
|
89-97%
|
85-94%
|
87-101%
|
코아사이언스 coresciences Korea ELK Biotechnology CO.,LTD ELK (Wuhan) Biotechnology CO.,Ltd. 한국 대리점 ELISA antibody 항체 면역학 연구 세포배양 분자생물학 시약
'ELISA,항체,단백질' 카테고리의 다른 글
- Total
- Today
- Yesterday
- gradient gel
- allview PAGE buffer
- 조직염색절편제작
- 막필터
- 조직절편제작
- OPV
- 조직절편
- 코아사이언스
- Sterlitech
- Coresciences
- OLED
- time release pellets
- 형광염색
- 후나코시
- 건스터바이오텍
- material science
- 콘드로이틴 황산 올리고당
- solar cells
- 파라핀 블럭
- matrix-driven delivery pellet
- Funakoshi
- 연속절편
- 고수용성 콘드로이틴
- 바이오헤저드백
- filter
- 바이오하자드백
- 미니멸균백
- 파라핀 블록
- 면역화학분석
- 오토클레이브백
일 | 월 | 화 | 수 | 목 | 금 | 토 |
---|---|---|---|---|---|---|
1 | 2 | |||||
3 | 4 | 5 | 6 | 7 | 8 | 9 |
10 | 11 | 12 | 13 | 14 | 15 | 16 |
17 | 18 | 19 | 20 | 21 | 22 | 23 |
24 | 25 | 26 | 27 | 28 | 29 | 30 |